Superdex 200 Increase 10/300 GL Manual: A Comprehensive Overview
This manual details the Superdex 200 Increase 10/300 GL column, focusing on size exclusion chromatography for biomolecule purification, offering instructions and specifications.
The Superdex 200 Increase 10/300 GL is a prepacked column designed for efficient gel filtration chromatography, a technique used to separate molecules based on size. This column, from GE Healthcare Life Sciences, is particularly well-suited for applications requiring purification of biomolecules like proteins and peptides. It’s a valuable tool for researchers needing high-resolution separation and reliable performance.
This manual provides comprehensive guidance on utilizing the column effectively, covering everything from initial setup and equilibration to chromatographic separation and troubleshooting. Understanding its specifications and operational parameters is crucial for achieving optimal results. The Superdex 200 Increase series offers enhanced capacity and resolution, making it ideal for both analytical and preparative purposes.
Intended Use and Applications

The Superdex 200 Increase 10/300 GL column is primarily intended for the separation of proteins, protein complexes, and other biomolecules based on their hydrodynamic volume. It excels in small-scale preparative purification, functioning effectively as a polishing step within larger purification workflows. Researchers can achieve milligram quantities of highly homogenous target proteins using this column.
Specific applications include sample desalting, buffer exchange, and determination of protein molecular weight. It’s also suitable for analyzing protein aggregation states and removing contaminants based on size. The column’s capabilities extend to purifying DNA fragments (under 200 base pairs) and other biomolecules requiring size-based separation, making it versatile for diverse research needs.
Column Specifications and Dimensions
The Superdex 200 Increase 10/300 GL column is a prepacked column designed for efficient size exclusion chromatography. It features a column diameter of 10 mm and a length of 300 mm, providing a bed volume of approximately 24 ml. This configuration is optimized for smaller sample volumes, typically ranging from 25 to 500 µl, making it ideal for analytical and small-scale preparative applications.
The column utilizes a cross-linked agarose matrix, ensuring robust performance and chemical stability. It’s delivered ready for use, eliminating the need for packing. Proper inspection of the delivered components against the provided list is crucial before initial use to confirm completeness and prevent operational issues.

Column Performance Characteristics
This section outlines key performance aspects, including fractionation range, pressure limits, and bed volume, crucial for optimal separation and reliable results.
Fractionation Range
The Superdex 200 Increase 10/300 GL column excels at separating molecules based on size, offering a fractionation range typically spanning 10 kDa to 600 kDa. This makes it ideally suited for a broad spectrum of biomolecules, including proteins, protein complexes, and even larger structures like oligonucleotides.
However, the precise effective range can be influenced by factors such as mobile phase composition and flow rate. Calibration with appropriate standards, as detailed later in this manual, is essential to accurately determine the elution volume for specific target molecules and optimize separation. Understanding this range is fundamental for successful purification and analysis.
Pressure and Flow Rate Limits
Maintaining optimal pressure and flow rates is crucial for column performance and longevity. The Superdex 200 Increase 10/300 GL column is designed for operation at pressures up to 0.5 MPa (72.5 psi). Exceeding this limit can damage the column matrix and compromise its separation capabilities.
Recommended flow rates typically range from 0.4 to 1.0 mL/min, though this can be adjusted based on the specific application and desired resolution. Lower flow rates generally improve resolution but increase run times. Always monitor the system pressure during operation and adhere to the specified limits to ensure reliable and consistent results.
Bed Volume
Understanding the bed volume is essential for accurate sample loading and elution calculations. The Superdex 200 Increase 10/300 GL column possesses a total bed volume of approximately 24 mL. This value represents the total void volume within the column matrix and is critical when determining the appropriate sample volume to apply.
Accurate knowledge of the bed volume allows for precise calculation of elution volumes and facilitates efficient fraction collection. It’s important to consider this volume when optimizing purification protocols and scaling up separations. Utilizing the correct bed volume ensures optimal column performance and maximizes recovery of the target protein or biomolecule.

Preparing the Column for Use
Proper preparation involves storage considerations, initial setup procedures, and a crucial equilibration step to ensure optimal chromatographic performance and reliable results.
Storage and Initial Setup
Upon receiving the Superdex 200 Increase column, verify all components are present according to the packing list. Store the column refrigerated at 4-8°C in the storage buffer – typically 20% ethanol – to maintain the resin’s integrity and prevent microbial growth.
Before first use, carefully remove the protective end caps. Connect the column to your chromatography system, ensuring proper flow direction as indicated on the column body.
Avoid introducing air bubbles into the system, as they can disrupt flow and affect separation quality. Gently flush the column with several column volumes of the equilibration buffer to remove the storage solution completely before proceeding with sample loading.
Equilibration Procedure
Proper equilibration is crucial for optimal performance of the Superdex 200 Increase column. Begin by flushing the column with at least 1-2 column volumes of the chosen running buffer. Monitor the UV absorbance at 280nm to ensure the baseline stabilizes, indicating complete removal of the storage solution (typically 20% ethanol).
Continue equilibration until a stable baseline is achieved and the pH and conductivity of the eluent match the desired running conditions. This process may require several column volumes, depending on the initial storage buffer concentration and the running buffer composition.
Thorough equilibration ensures consistent and reproducible results.
Sample Preparation Guidelines
Effective sample preparation is vital for successful separation using the Superdex 200 Increase column. Samples should be fully dissolved in a buffer compatible with the chosen mobile phase, ensuring no precipitation occurs. Filtration through a 0.22 µm filter is highly recommended to remove particulate matter that could clog the column.
The sample volume should be optimized for the column dimensions; typically, 25-500 µl is suitable for the 10/300 GL column. Avoid highly viscous or concentrated samples, as they can lead to peak broadening and increased backpressure.
Degassing the sample prior to injection is also beneficial.

Chromatographic Separation and Calibration
Accurate calibration is crucial for determining molecular weights. Utilize standard proteins and create a calibration curve for reliable size exclusion chromatography results.
Calibration Standards
Establishing a robust calibration curve requires utilizing appropriate standards. GE Healthcare Life Sciences offers dedicated gel filtration calibration kits, featuring a selection of proteins with well-defined molecular weights. These kits, available for HiLoad and HiPrep columns (like the Superdex 75, Sephacryl S-300 HR, and S-200), provide reliable reference points.
Employing these standards allows for accurate determination of the molecular weight of unknown samples. The provided figures demonstrate chromatographic separations and calibration curves generated using these standards, illustrating the relationship between elution volume and molecular weight. Careful selection and preparation of these standards are paramount for achieving precise and reproducible results in size exclusion chromatography.
Creating a Calibration Curve
A precise calibration curve is essential for accurate molecular weight determination. Begin by running a series of calibration standards with known molecular weights through the Superdex 200 Increase 10/300 GL column. Plot the logarithm of their molecular weights against their respective elution volumes.
The resulting graph should exhibit a linear relationship. Utilize linear regression analysis to generate an equation representing this relationship. This equation then serves as the basis for calculating the molecular weight of unknown samples based on their elution volumes. Refer to the example curves generated for HiPrep Sephacryl columns as a visual guide for expected curve shapes and linearity.
Using Calibration Kits (HiLoad, HiPrep)
GE Healthcare Life Sciences offers convenient calibration kits, such as those for HiLoad and HiPrep columns, to simplify curve creation. These kits contain a pre-defined set of protein standards with accurately known molecular weights. Follow the kit’s instructions for sample preparation and application to the Superdex 200 Increase 10/300 GL column.
Analyze the elution volumes of each standard and plot the data as described previously. The provided standards, like those shown in Figure 8 and 9 for HiLoad 75 and HiPrep S-300/S-200, facilitate a robust and reliable calibration. Ensure proper data handling for accurate molecular weight estimations.

Operational Parameters
Optimal performance relies on carefully selected mobile phases and flow rates, alongside efficient fraction collection strategies tailored to your specific purification needs.
Mobile Phase Selection
Choosing the right mobile phase is crucial for successful separations. Generally, aqueous buffers are employed, maintaining protein stability and compatibility. Common buffers include phosphate, Tris, and HEPES, adjusted to the desired pH for optimal protein solubility and activity.
The ionic strength of the mobile phase can influence protein elution; lower ionic strength often enhances resolution. Additives like glycerol or arginine can minimize protein aggregation and non-specific interactions with the column matrix.
Avoid buffers containing precipitating agents or components that may damage the column. Filtration of the mobile phase through a 0.22 µm filter is essential to prevent clogging and maintain column performance. Always degas the mobile phase before use to eliminate air bubbles.
Flow Rate Optimization
Optimizing the flow rate is vital for achieving optimal resolution and separation speed. The Superdex 200 Increase 10/300 GL column performs best within a specific flow rate range, typically between 0.4 and 1.0 mL/min. Lower flow rates generally improve resolution but extend run times.
Higher flow rates decrease run times but may compromise resolution. Experimentation is key to finding the ideal balance for your specific application and sample.
Monitor the column pressure during operation; exceeding the recommended pressure limit can damage the column. Consistent flow is crucial; use a calibrated pump to ensure accurate and reproducible results. Avoid abrupt flow rate changes.
Fraction Collection
Efficient fraction collection is essential for isolating purified target proteins. Based on the calibration curve established earlier, predict the elution volume of your protein of interest. Begin collecting fractions slightly before the predicted elution time to ensure complete recovery.
Fraction size should be optimized based on peak volume and desired purity. Smaller fractions provide higher resolution but require more handling. Use a fraction collector compatible with the column dimensions and flow rate.
Analyze collected fractions using appropriate methods (e.g., SDS-PAGE, activity assays) to identify those containing the target protein. Pool the desired fractions for further processing.

Purification Applications
This column excels in small-scale preparative purification, particularly as a polishing step, yielding milligram amounts of highly homogenous target proteins efficiently.
Small-Scale Preparative Purification
The Superdex 200 Increase 10/300 GL column is particularly well-suited for small-scale preparative purification tasks. Its capacity allows for efficient purification of target proteins within the 25 to 500 µl sample volume range. This makes it an ideal choice when working with limited sample amounts, common in early-stage research or when dealing with precious biomaterials. The column’s fractionation capabilities ensure the collection of highly purified protein fractions, minimizing the need for further purification steps. It’s a robust solution for obtaining milligram quantities of your desired protein, streamlining your workflow and maximizing yield. Careful optimization of flow rates and mobile phase selection is crucial for achieving optimal separation and recovery during these applications.
Polishing Step in Purification Procedures
The Superdex 200 Increase 10/300 GL column excels as a polishing step within multi-stage purification workflows. Following initial purification methods like affinity or ion exchange chromatography, this size exclusion column effectively removes aggregates, misfolded proteins, and other impurities based on their size. This final polishing step significantly enhances the homogeneity and purity of the target protein, crucial for downstream applications like structural studies or bioassays. Utilizing this column ensures a highly refined protein preparation, improving the reliability and reproducibility of experimental results. It’s a valuable addition to any purification protocol demanding high-quality protein samples.
Target Protein Amounts (mg scale)
The Superdex 200 Increase 10/300 GL column is particularly well-suited for small-scale preparative purification, efficiently handling target protein amounts in the milligram (mg) range. Its capacity allows for the purification of 25 to 500 µl samples, yielding significant quantities of highly homogenous protein. This makes it ideal for applications requiring moderate amounts of purified protein, such as initial characterization, enzyme assays, or seed stock preparation for larger-scale production. The column’s performance ensures both high recovery and purity, delivering reliable results when working with precious protein samples.

Troubleshooting
Addressing common issues like low resolution, peak broadening, or pressure problems ensures optimal performance with the Superdex 200 Increase 10/300 GL column.
Low Resolution
Low resolution during separation often indicates issues with sample preparation or column performance. First, ensure your sample is properly filtered using a 0.22 µm filter to remove particulate matter that can cause band broadening. Verify the mobile phase is degassed to prevent air bubbles from disrupting flow and resolution.
Insufficient sample dilution can also lead to poor peak shape. Optimize the injected sample volume to avoid column overloading. Check the flow rate; excessively high flow rates reduce interaction time and decrease resolution. Finally, confirm the column is adequately equilibrated with the chosen mobile phase before sample application, as incomplete equilibration can significantly impact separation quality.
Peak Broadening
Peak broadening signifies reduced separation efficiency and can stem from several factors. A primary cause is sample-column matrix interactions; ensure your sample is compatible with the Superdex 200 Increase column and consider adding a small amount of non-ionic detergent to minimize these interactions.
Additionally, improper sample preparation contributes to broadening. Thoroughly dissolve your sample and filter it through a 0.22 µm filter to remove aggregates and particulates. Confirm the mobile phase is properly degassed, as dissolved gases can cause peak distortion. Finally, verify the flow rate is optimized; excessively high flow rates can reduce resolution and broaden peaks.
Pressure Issues
Elevated system pressure during operation indicates potential column blockage or restrictions within the fluid path. Immediately reduce the flow rate to mitigate further pressure build-up and potential damage to the column. Inspect the inlet and outlet lines for kinks or obstructions, and ensure the connecting tubing is of appropriate diameter.
If the pressure persists, column cleaning is crucial. Perform a cleaning-in-place procedure using recommended buffers to remove accumulated particulates or precipitated proteins. Verify the mobile phase is properly filtered. Exceeding the maximum pressure limit (refer to column specifications) can irreversibly damage the column matrix, voiding the warranty.

Maintenance and Care
Regular column cleaning and proper storage are vital for maintaining performance and extending the Superdex 200 Increase 10/300 GL column’s lifespan.
Column Cleaning
Routine cleaning is essential to prevent matrix compression and maintain optimal column performance. After each use, or at least weekly with frequent operation, flush the column with several bed volumes of a suitable cleaning solution. A common and effective cleaning solution is 1M NaCl in the mobile phase buffer. This helps to remove strongly bound proteins and other contaminants.
For more thorough cleaning, especially after processing samples containing lipids or nucleic acids, consider using a 60% aqueous solution of isopropanol, followed by equilibration with the starting buffer. Avoid using strong chaotropic agents or detergents, as these can damage the column matrix. Always ensure complete removal of the cleaning solution before resuming normal operation by thoroughly equilibrating the column with the mobile phase.
Storage Conditions
Proper storage is crucial for preserving the column’s functionality and extending its lifespan. When not in use for extended periods (more than a few days), store the Superdex 200 Increase 10/300 GL column in the manufacturer’s recommended storage buffer – typically a 20% ethanol solution. This prevents microbial growth and maintains the hydrated state of the matrix.
Always avoid allowing the column to dry out, as this can cause irreversible damage to the porous structure. Store the column upright to prevent settling of the matrix. Keep the column in a cool, dark place, ideally at 4-8°C, to minimize degradation. Before resuming use after storage, thoroughly equilibrate the column with several bed volumes of starting buffer.
Column Lifetime
The lifespan of the Superdex 200 Increase 10/300 GL column is dependent on several factors, including sample load, flow rate, and the effectiveness of cleaning procedures. Generally, with careful use and regular maintenance, the column can provide consistent performance for a substantial number of runs – often exceeding 200-300 purifications.
However, frequent use with highly aggregating samples or insufficient cleaning can significantly reduce its lifetime. Signs of column degradation include decreased resolution, peak broadening, and increased backpressure. Implementing a robust cleaning protocol after each use, and avoiding harsh chemicals, will maximize the column’s longevity and maintain optimal separation performance.

Safety Precautions
Always handle mobile phases with care, adhering to standard laboratory safety protocols, and ensure proper waste disposal to mitigate potential hazards during operation.
Handling of Mobile Phases
When working with mobile phases, prioritize safety by wearing appropriate personal protective equipment, including gloves and eye protection, to prevent skin and eye contact. Always consult the Safety Data Sheet (SDS) for each mobile phase component to understand specific hazards and handling instructions. Ensure adequate ventilation in the work area to minimize inhalation of vapors.
Carefully prepare mobile phases according to established protocols, using high-quality reagents and solvents. Avoid mixing incompatible chemicals, and always add reagents in the correct order. Properly label all mobile phase containers with their contents and hazard warnings. Store mobile phases in a cool, dry place, away from direct sunlight and heat sources. Dispose of waste mobile phases according to local regulations and laboratory procedures.
Waste Disposal
Proper waste disposal is crucial when using the Superdex 200 Increase 10/300 GL system. Collect all waste streams – including used mobile phases, wash solutions, and column effluent – in appropriately labeled containers. Segregate waste based on its chemical composition and hazard level, following your institution’s guidelines.
Mobile phases often contain salts, buffers, and potentially hazardous organic solvents; therefore, avoid pouring them down the drain. Dispose of organic waste in designated solvent waste containers. Aqueous waste may require neutralization or pre-treatment before disposal. Consult your environmental health and safety department for specific disposal procedures and regulations applicable to your location and the chemicals used.
General Laboratory Safety
Always adhere to standard laboratory safety protocols when operating the Superdex 200 Increase 10/300 GL system. Wear appropriate personal protective equipment (PPE), including safety glasses, gloves, and a lab coat, to prevent exposure to chemicals and biological samples. Ensure adequate ventilation in the work area, especially when handling volatile solvents.
Be mindful of potential hazards associated with high-pressure liquid chromatography (HPLC) systems, such as leaks or spills. Familiarize yourself with the location of emergency equipment, including eyewash stations and safety showers. Avoid eating, drinking, or smoking in the laboratory. Practice good housekeeping to maintain a safe and organized workspace, minimizing the risk of accidents.